01 / Technical reference
Document overview
SP25 industrial rotary screw specifications for fixed-speed and variable-speed configurations. The sheet separates fixed-speed and VFD performance figures by pressure; do not combine their ratings.
Published technical specifications
SP25 fixed-speed rated flow
Scroll sideways to compare all model columns.
| Specification | SP25-200 | SP25-250 | SP25-300 | SP25-350 |
|---|---|---|---|---|
| Motor rating (HP) | 200 | 250 | 300 | 350 |
| Capacity at 100 psig (ACFM) | 1,038.9 | 1,275.2 | 1,385.1 | 1,540.3 |
| Capacity at 125 psig (ACFM) | 933.8 | 1,133.3 | 1,261.8 | 1,380.2 |
| Capacity at 150 psig (ACFM) | 835.9 | 1,021.4 | 1,123.7 | 1,252.9 |
| Capacity at 175 psig (ACFM) | Not listed | 917.2 | 1,019.1 | 1,115.8 |
Data transcribed from the SP25 fixed-speed table; Not listed reflects a dash in the PDF.
SP25 variable-speed rated flow
Scroll sideways to compare all model columns.
| Specification | SP25-200 VFD | SP25-250 VFD | SP25-300 VFD | SP25-350 VFD |
|---|---|---|---|---|
| Motor rating (HP) | Not listed | 250 | 300 | 350 |
| Capacity at 100 psig (ACFM) | Not listed | 1,267.7 | 1,391.3 | 1,535.6 |
| Capacity at 125 psig (ACFM) | Not listed | 1,129.1 | 1,264.6 | 1,380.1 |
| Capacity at 150 psig (ACFM) | Not listed | 1,029.6 | 1,118.8 | 1,263.1 |
| Capacity at 175 psig (ACFM) | Not listed | 914.5 | 1,021.2 | 1,118.2 |
PDF asterisk markings apply to certain listed VFD values; refer to the original table and CAGI data sheet for test conditions.
Published package dimensions
| Configuration | Length x width x height (in) |
|---|---|
| Base open | 120 x 70 x 81.8 |
| Base enclosed | 120 x 70 x 82.5 |
Published equipment features
- Premium-efficiency TEFC electric motor, Wye-Delta starter and phase monitor listed.
- Integrated VFD options, optimized screw elements and service-access features described.
- Structural skid, vibration isolation and PalExtra 44 factory fluid specified.
Application guidance
Use this reference when reviewing motor ratings, pressure-dependent flow, starter configurations and installation requirements. Electrical and pressure ratings must be checked for the exact motor, voltage and operating setpoint.
Technical questions / Manufacturer reference
Frequently asked questions
Which horsepower sizes are included in the SP25 documentation?
The SP25 sheet lists 200; 250; 300; 350 hp models and compares pressure-dependent performance.
What fixed-speed airflow is listed at 100 psig for SP25-200 and SP25-350?
At 100 psig the published SP25-200 value is 1,038.9 ACFM and the SP25-350 value is 1,540.3 ACFM.
Are SP25 fixed-speed and variable-speed ratings interchangeable?
No. The sheet separates fixed-speed and VFD performance figures by pressure; do not combine their ratings. Use the table that matches the actual control configuration.
Specifications depend on the model, configuration and document revision. Consult the manufacturer PDF linked on this page for the complete reference.