SP25 industrial rotary screw specifications for fixed-speed and variable-speed configurations.

01 / Technical reference

Document overview

SP25 industrial rotary screw specifications for fixed-speed and variable-speed configurations. The sheet separates fixed-speed and VFD performance figures by pressure; do not combine their ratings.

Published technical specifications

SP25 fixed-speed rated flow

Scroll sideways to compare all model columns.

SP25 fixed-speed rated flow
SpecificationSP25-200SP25-250SP25-300SP25-350
Motor rating (HP)200250300350
Capacity at 100 psig (ACFM)1,038.91,275.21,385.11,540.3
Capacity at 125 psig (ACFM)933.81,133.31,261.81,380.2
Capacity at 150 psig (ACFM)835.91,021.41,123.71,252.9
Capacity at 175 psig (ACFM)Not listed917.21,019.11,115.8

Data transcribed from the SP25 fixed-speed table; Not listed reflects a dash in the PDF.

SP25 variable-speed rated flow

Scroll sideways to compare all model columns.

SP25 variable-speed rated flow
SpecificationSP25-200 VFDSP25-250 VFDSP25-300 VFDSP25-350 VFD
Motor rating (HP)Not listed250300350
Capacity at 100 psig (ACFM)Not listed1,267.71,391.31,535.6
Capacity at 125 psig (ACFM)Not listed1,129.11,264.61,380.1
Capacity at 150 psig (ACFM)Not listed1,029.61,118.81,263.1
Capacity at 175 psig (ACFM)Not listed914.51,021.21,118.2

PDF asterisk markings apply to certain listed VFD values; refer to the original table and CAGI data sheet for test conditions.

Published package dimensions

Published package dimensions
ConfigurationLength x width x height (in)
Base open120 x 70 x 81.8
Base enclosed120 x 70 x 82.5

Published equipment features

  • Premium-efficiency TEFC electric motor, Wye-Delta starter and phase monitor listed.
  • Integrated VFD options, optimized screw elements and service-access features described.
  • Structural skid, vibration isolation and PalExtra 44 factory fluid specified.

Application guidance

Use this reference when reviewing motor ratings, pressure-dependent flow, starter configurations and installation requirements. Electrical and pressure ratings must be checked for the exact motor, voltage and operating setpoint.

Technical questions / Manufacturer reference

Frequently asked questions

Which horsepower sizes are included in the SP25 documentation?

The SP25 sheet lists 200; 250; 300; 350 hp models and compares pressure-dependent performance.

What fixed-speed airflow is listed at 100 psig for SP25-200 and SP25-350?

At 100 psig the published SP25-200 value is 1,038.9 ACFM and the SP25-350 value is 1,540.3 ACFM.

Are SP25 fixed-speed and variable-speed ratings interchangeable?

No. The sheet separates fixed-speed and VFD performance figures by pressure; do not combine their ratings. Use the table that matches the actual control configuration.

Specifications depend on the model, configuration and document revision. Consult the manufacturer PDF linked on this page for the complete reference.

Need help with the next step?

Find the right compressor solution.

Discuss your required airflow, operating pressure, installation conditions or model selection with the Sullivan-Palatek sales team.